Condor Pressure Switch, 140/175 PSI, 4-Port, 1/4" FPT #1163D4

(No reviews yet) Write a Review
Shipping:
Calculated at Checkout
  • Condor Pressure Switch, 140/175 PSI, 4-Port, 1/4" FPT #1163D4
  • Condor Pressure Switch, 140/175 PSI, 4-Port, 1/4" FPT #1163D4
  • Condor Pressure Switch, 140/175 PSI, 4-Port, 1/4" FPT #1163D4
  • Condor Pressure Switch, 140/175 PSI, 4-Port, 1/4" FPT #1163D4
Price: $34.81

Description

Condor 11KC2E OEM pressure switch replacement. 4-port, 1/4" female NPT ports with on/off switch and 90-degree compression-style unloader valve.

Replace the pressure switch if the compressor no longer cuts in or cuts out at the designated pressure (PSI), if the unit doesn't turn on or off, or if there is an obvious air leak from the contacts or manifold.

If the small unloader (bleeder) valve on or under your switch leaks constantly AFTER the unit shuts off, don't replace this part, replace the in-tank check valve. Most pressure switches have a bleeder valve which has a 1/4" plastic or copper line routing to it.

Specifications

OEM Part Number: 11KC2E
Pressure Settings: 140/175 PSI
Manifold Type: 1/4" NPT, 4-port
Auto/Off Function: Yes
Unloader Type: 1/4" (EV1WBi); 1/4" compression
Strain Relief Left: None
Strain Relief Right: None
Weight: .70 lbs
Manual Switch Action: Auto/Off
Differential: 30 to 65 PSI
Range: 40 to 175 PSI
Electrical Contact Form: DPST
Action: Standard
NEMA Rating: 1
HP @ 1 Phase: 120V2 HP
HP @ 1 Phase: 240V3 HP
Temp. Range: -22° to 257°F
Standards: CSA-certified; UL Listed
AC Contact Rating: 26A @ 240V

Extra Details

  • 2-pole Single Phase (N.C.)
  • Def. Purpose Switching Capacity: 26 FLA/156 LRA up to 240V
  • Gen. Purpose Switching Capacity:
    • 2 HP @120V
    • 3 HP @240V
  • NEMA A600 Pilot Duty
  • Acc. to EN 60947
  • 4.0 kW (AC3), Ue=240V (1~)
  • Cut-out pressures up to 225 psi
  • NEMA 1 Enclosure
  • Flange = Die-cast aluminum
  • Adjustable range and differential
  • Wide variety of unloader valves

Technical Documents

Rated insulation voltage Ui = 500 V
Motor switching capacity (AC 3) [Ue=240 V (1~)] = 4,0 kW
Motor switching capacity (UL 508, CSA 22.2) [Ue=240 V (1~) / Ue=120 V (1~)]     = 3,0 HP / 2,0 HP
Electrical life (UL 508, CSA 22.2) [Ue=240 V dc; 2,7A] = 0,5 HP
Electrical life (AC 3) (cycles) >= 1 x 105
Mechanical life (cycles) >= 5 x 105
Max. electrical cycles (Cycles/h) = 120
Max. mechanical cycles (Cycles/h) = 600
Rated operational current Ie (EN 60947) [at 240 V AC] = 20 A
Rated operational current Ie (UL/CSA) [at 240 V AC] = 26 A
Bursting strength Pz >= 35 bar
Permissible medium temperature Air = -5...+80 °C
Permissible medium temperature Water = +70 °C
Degree of Protection acc. to EN 60529 = IP 44
Conductor cross-section 1 .. fine stranded cable 1 x / 2 x = 2,5 / 2,5 mm2
Conductor cross-section 1 rigid cable 1 x / 2 x = 2,5 / 2,5 mm2
View AllClose

0 Reviews